Choose the appropriate thickness of insulation in accordance with the prescriptions (eg. DIN 1988), who respect the significant parameters for selection of the required insulation thicknesses compared to the dimension of the pipe, purpose and flow-conduit pipe.
In relation to the constantly more energy prices in the case of larger objects important tests and calculations. The optimum thickness of insulation so choose, that achieved the lowest costs in respect of energy prices, the average temperature difference, time work and insulating ability of the material.
When budgets pipe insulation is necessary to respect the special conditions: distributive flow, reinforcement and environmental conditions.
Area.of application ISO , SSV, SSL |
Insulation thickness 4mm |
Insulation thickness 9mm |
Insulation thickness 13mm |
Insulation thickness 30mm |
Heating ISO, SV, SSV |
pipes without special requirements - directly in front of the user, Controlled heat consumption in the heated space. | pipes without special requirements - directly in front of the user, Controlled heat consumption in the heated space. |
– connection length max. 8 m – a central hub with associated fittings |
top lines and the main electrical supply - connections (bigger than 8 m) in unheated space, on the external walls and walls that border unheated space |
Hot water distribution pipes ISO, SV, SSV |
smaller heat pipes to DN20, in apartment buildings, where pipelines are not involved, including the circulatory flow | connection length max. 8 m, If the wall thickness does not allow of increased thickness | – connection length max. 8 m - central distributor and associated reinforcement | – top lines and the main electrical supply - connectors (bigger then 8 m and circulation pipes) |
Distribution of cold water SV, SSL |
– freely lay pipelines in the unheated area - laid in the channel without heating system - laid in the wall or on the floor and away from the heating system |
loosely laid in the heated area | – laid in the channel next to the heating system - laid in the wall or the floor next to the heating system | loosely laid in the channel or at increased relative humidity |
Waste water SV, SSL |
Solar systems Gumaflex VT Mineral wool |
ISO insulating tubes Assortment Characteristics Area of application