Product type | EPE - ISO | Invocation - SSL | EPE - SV |
BASIC MATERIAL | Expanded polyethylene gray | Expanded polyethylene gray | Expanded polyethylene gray |
CO EXTRUDED PROTECTIVE FOIL |
Metal. silver foil of not expanded polyethylene | ||
CO EXTRUDED ZIP |
Zip of the not extruded polyethylene | ||
Density SIST ISO 845 |
30kg/m³ ±10% | 35kg/m³ ±10% | 30kg/m³ ±10% |
Cell structure SIST ISO DIS 7214 |
Small, closed cell | Small, closed cell | Small, closed cell |
The visible surface | Dark grey | Metallic silver | Dark grey |
Thermal conductivity (λ) ISO/DIS 8497 (DIN 526139) |
λ10 °c:0,032W/mKλ40 °c:0,039W/mK | λ10 °c:0,032W/mKλ40 °c:0,039W/mK | λ10 °c:0,032W/mK
λ40 °c:0,039W/mK |
Temp. fields of Application | 0 ºC do + 95 ºC | -40 ºC do + 95 ºC | 8 ºC do + 95 ºC |
Coef. dif. water vapor (μ) prEN 13469 (DIN 52615) |
>5000 | >7000 | >2500 |
Water absorption SIST ISO 2896 |
Soak 1,7% in 7 days (on the lateral intersection) | Soak 1,7% in 7 days (on the lateral intersection) | Soak 1,7% in 7 days (on the lateral intersection) |
UV stability | Need protection from sun | Need protection from sun | Need protection from sun |
Ozone stability | Excellent | Excellent | Excellent |
Smell | Neutral | Neutral | Neutral |
Chemical stability | Excellent for normal use | Excellent for normal use | Excellent for normal use |
Elasticity | Excellent | Excellent | Excellent |
Tensile characteristics
SIST ISO 1798 |
Hardness tensile: 0,35(±0,02)N/mm² Elongation at break: 49,8(+/-5,4)% |
Hardness tensile: 0,38(±0,02)N/mm² Elongation at break: 54,8(+/-5,4)% |
Hardness tensile: 0,35(±0,02)N/mm² Elongation at break: 49,8(+/-5,4)% |
Pressed characteristics SIST ISO 3386-1 |
Deformation (%)10 25 50
Pres. (N/mm²): 0,01 0,03 0,08 |
Deformation (%)10 25 50
Pres. (N/mm²): 0,01 0,04 0,09 |
Deformation (%)
10 25 50 Pres. (N/mm²): 0,01 0,03 0,08 |
Thermal stability SIST ISO 2796 after 24 hours at |
-30ºC:-0,1%+90 ºC:-3,7% | -30ºC:-0,1%+90 ºC:-3,7% | -30ºC:-0,1%
+90 ºC:-3,7% |
The impact of corrosion | Insulation protects the pipes from corrosion | Insulation protects the pipes from corrosion | Insulation protects the pipes from corrosion |
Eagerness DIN 4102 |
Hardly flammable B1(03-P-BWU-16/05/12 FMPA Stuttgart) |
Hardly flammable B1(03-P-BWU-16/05/12 FMPA Stuttgart) (*B2) |
Hardly flammable B1
(03-P-BWU-16/05/12 |
ISO insulating tubes Assortment Characteristics Area of application